CTS#41887
68kW Barry Brown LSQWF60M Water Chiller (Air-cooled) 2008 with Glycol Tank, Pump and Heat Exchanger
Condenser
Coils are consisting of seamless copper
tubes mechanically expanded into blue
hydrophilic aluminum fins.
Refrigerant Circuit
Copper tube connected with charge valves, filter drier, bypass
solenoid valve, sight glass, Gas-liquid separator, thermostatic
expansion valve, high & low pressure switch.
Chiller vessel
Galvanized heat exchangers complete with BSM water in/out
connections for shell and tube heat exchanger and BSM
flange type connections for larger chillers
Structures
Unit panels, frame and base are made from galvanized steel
protected with polyester powder coating to ensure total
resistance to atmospheric agents.
Compressor (s)
All models up to 180k.w are fitted with
Maneurop scroll compressors.
Chillers over 180k.w are fitted with semi
hermetic screw compressors.
Fans
External rotor type axial fans, equipped
with three phase direct drive motors,
low noise 8 pole, protection level IP54,
provided with a protective outlet grille.
Electrical Panel
• Compressor contactor
• Fan contactor
• Compressor protection breaker
• Fan protection breaker
• Phase sequence relay
• Microprocessor with function display
(display only for master/packaged unit)
• Pre-arranged interface for remote on/off
control
• Pre-arranged interface for compressor
running light
• Pre-arranged interface for alarm light
Microprocessor
Microprocessor board functions:
• Inlet water temperature control by thermostatic
and capacity step control.
• Compressor operation hour count
• Compressor operation rotation
• On/off control
• Defrosting control(heat pump)
• Low temperature device (accessory)
control
• Alarm reset
• Memory with alarm history (with memory
of operating parameters)
• Local or remote control operation
• Machine status display for each circuit
Alarm management:
a) Signal alarms:
Unit maintenance, compressor maintenance,
board fault or disconnection fault,
b) Circuit alarms:
high pressure, low pressure, compressor
thermal cut-out, oil differential, fan cut-out,
antifreeze, pressure differential, enabled
probes fault or absent
c) Major alarms
No water flow, phase monitor alarm, pump
cut-out, water probe absent/fault
|
|
|
|
|
|
|
PLEASE NOTE
Since we buy, sell and change our listings daily, all items listed are
subject to prior sale, withdrawal, or other disposition. And while we strive for
complete accuracy, we cannot be responsible for errors or omissions in equipment
specifications, descriptions, typographical errors etc. |
|
|
Phone +61 (0)3 8792 9777
Fax +61 (0)3 8792 9788 Email
|
|
|
|